Cords Per Year
How much firewood your house burns in a year, from things you already know. It is a ballpark by design, and the receipt at the bottom shows every step.
1 · Climate
Where the house is
Blended from Santa Rosa, CA (10 mi), Napa, CA (35 mi), Ukiah, CA (50 mi), San Francisco, CA (55 mi). Elevation used: 300 ft. That gives about 3,291 heating degree-days at base 65 °F.
2 · The house
What the heat has to get through
Enter the floor area you actually keep warm with wood.
3 · Comfort
How warm you keep it
People, appliances and winter sun heat the house for free; the model subtracts that before counting a degree-day.
4 · The wood
What's in the pile
5 · The stove
How the heat gets into the room
Heat loss rate by path, 588 BTU per hour per °F
- Walls105 · 18%
- Roof70 · 12%
- Floor100 · 17%
- Glass140 · 24%
- Air leaks173 · 29%
The receipt
- Heat loss rate
- the house shell: 1,322 ft² of wall, 240 ft² of glass, 16,000 ft³ of air
- 588 BTU/h·°F
- Effective thermostat
- 64.0 °F
- Free heat
- people, appliances and sun: 3,333 BTU/h
- 5.7 °F
- Balance point
- outside temperature below which the stove has to run
- 58.3 °F
- Degree-days
- below the balance point, summed over the year
- 1,732 °F·days
- Heat the stove must deliver
- = UA × degree-days × 24 h
- 24.4 MBTU
- Useful heat per cord
- Pacific madrone 30.9 MBTU × 72% stove × 1.00 moisture × 0.92 burn habits
- 20.5 MBTU
- Full cords (4 × 4 × 8 ft)
- ≈ 3.6 face cords of 16-inch wood · ≈ 2.7 tons
- 1.2
Cords by month
Jul
Aug
Sep
Oct
0.2Nov
0.3Dec
0.2Jan
0.2Feb
0.1Mar
0.1Apr
May
Jun
The same heat, if it came from somewhere else
257
therms of gas
95% furnace
297
gallons of propane
90% furnace
2,557
kWh
heat pump, COP 2.8
7,160
kWh
electric resistance
Reality check
What this does and doesn't account for
- Heat demand = heat-loss rate × degree-days below the balance point × 24 h. The balance point is your effective thermostat setting minus the free heat from people, appliances and sun, divided by the loss rate (the variable-base degree-day method).
- Degree-days at any base temperature are estimated from monthly mean temperatures with the Erbs–Klein–Beckman method, which accounts for day-to-day swings. Monthly means come from the four nearest reference climates, weighted by distance and corrected 3.5 °F per 1,000 ft of elevation.
- Wall, roof and floor U-values include framing, air films and sheathing, so "R-13" walls behave like the R-10 or so they really are. Crawlspaces and basements get credit for being warmer than outdoors.
- Air leakage is modeled as natural air changes per hour × house volume × 0.018 BTU per ft³·°F, scaled by wind exposure. In old houses this is usually the biggest single path.
- Moisture: wetter wood loses heat to evaporation and burns less completely; green wood lands about 20% behind dry in this model.
- Stove efficiencies are typical higher-heating-value figures; the burn-habit factor covers the gap between a lab test and a real winter.
- Not modeled: thermal mass, humidity, duct or chimney losses beyond the efficiency figure, how full your cords really are (a "cord" from a seller varies by 20% or more), bark and rot, startup fires in shoulder seasons, and microclimates finer than the offset above. Treat the range as the honest answer and the single number as the center of it.